<LOGO>
FM Transmitter Measurement Report
Created: 2026-03-03 11-52-31
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.30 MHz 5/5, 84 dBuV 00s&10s
Pilot RDS Phase Difference
6.2 kHz 4.0 kHz 90 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 68 kHz 19034 11,3218
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,9 dBr 4,53 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"00s&10s " 249E 10 (Pop M) 1 0 1 1 11:51, 3.03.2026
RT
"MPB Radio 1 00s& "
AF EON
95.6, 96.3, 96.6, 96.9, 97.3, 97.7, 105.5 MHz 43B3, F84A, F84B, 2491
FM Scope Max at: 68 kHz MIN: 9 kHz % above 76 kHz: 11,3218 Acquired: 2026/03/03 11.51.27 Total samples: 19034 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,0 dBr MIN: 1,9 dBr AVE: 4,53 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2026/03/03 11.51.26) 11.38 11.40 11.42 11.44 11.46 11.48 11.50 0 2 4 6 Pm [dBr]